Product Description
Model
|
SUN-3.6K-SG05LP1-EU
|
SUN-5K-SG05LP1-EU
|
SUN-6K-SG05LP1-EU
|
SUN-7.6K-SG05LP1-EU
|
SUN-8K-SG05LP1-EU
|
|||||
Battery Input Data
|
||||||||||
Battery Type
|
Lead-acid or Lithium-ion
|
|||||||||
Battery Voltage Range (V)
|
40~60
|
|||||||||
Max. Charging Current (A)
|
90A
|
120A
|
135A
|
190A
|
190A
|
|||||
Max. Discharging Current (A)
|
90A
|
120A
|
135A
|
190A
|
190A
|
|||||
Charging Curve
|
3 Stages / Equalization
|
|||||||||
External Temperature Sensor
|
Yes
|
|||||||||
Charging Strategy for Li-Ion Battery
|
Self-adaption to BMS
|
|||||||||
PV String Input Data
|
||||||||||
Max. DC Input Power (W)
|
4680W
|
6500W
|
7800W
|
9880W
|
10400W
|
|||||
PV Input Voltage (V)
|
370V (125V~500V)
|
|||||||||
MPPT Voltage Range (V)
|
150~425V
|
|||||||||
Start-up Voltage (V)
|
125V
|
|||||||||
PV Input Current (A)
|
13A+13A
|
26A+26A
|
||||||||
Max. PV ISC (A)
|
17A+17A
|
34A+34A
|
||||||||
No.of MPPT Trackers
|
2
|
|||||||||
No.of Strings Per MPPT Tracker
|
1
|
2
|
||||||||
AC Output Data
|
||||||||||
Rated AC Output and UPS Power (W)
|
3600W
|
5000W
|
6000W
|
7600W
|
8000W
|
|||||
Max. AC Output Power (W)
|
3690W
|
5500W
|
6600W
|
8360W
|
8800W
|
|||||
Peak Power (off grid)
|
2 times of rated power, 10 S
|
|||||||||
AC Output Rated Current (A)
|
16.4/15.7
|
22.7/21.7
|
27.3/26.1
|
34.5/33
|
36.4/34.8
|
|||||
Max. AC Current (A)
|
18/17.2
|
25/23.9
|
30/28.7
|
38/36.3
|
40/38.3
|
|||||
Max. Continuous AC Passthrough (A)
|
35A
|
40A
|
50A
|
|||||||
Power Factor
|
0.8 leading to 0.8 lagging
|
|||||||||
Output Frequency and Voltage
|
50/60Hz; 220/230 / 240Vac (single phase)
|
|||||||||
Grid Type
|
Single Phase
|
|||||||||
Current Harmonic Distortion
|
THD<3% (Linear load<1.5%)
|
|||||||||
Efficiency
|
||||||||||
Max. Efficiency
|
97.60%
|
|||||||||
Euro Effiffifficiency
|
96.50%
|
|||||||||
MPPT Efficiency
|
99.90%
|
|||||||||
Protection
|
||||||||||
PV Input Lightning Protection
|
Integrated
|
|||||||||
Anti-islanding Protection
|
Integrated
|
|||||||||
PV String Input Reverse Polarity Protection
|
Integrated
|
|||||||||
Insulation Resistor Detection
|
Integrated
|
|||||||||
Residual Current Monitoring Unit
|
Integrated
|
|||||||||
Output Over Current Protection
|
Integrated
|
|||||||||
Output Shorted Protection
|
Integrated
|
|||||||||
Output Over Voltage Protection
|
Integrated
|
|||||||||
Surge protection
|
DC Type II / AC Type Ⅲ
|
|||||||||
Certifications and Standards
|
||||||||||
Grid Regulation
|
CEI 0-21, VDE-AR-N 4105, NRS 097, IEC 62116, IEC 61727, G99, G98, VDE 0126-1-1, RD 1699, C10-11
|
|||||||||
Safety EMC / Standard
|
IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2
|
|||||||||
General Data
|
||||||||||
Operating Temperature Range (℃)
|
-40~60℃, >45℃ Derating
|
|||||||||
Cooling
|
Natural cooling
|
|||||||||
Noise (dB)
|
<30 dB
|
|||||||||
Communication with BMS
|
RS485; CAN
|
|||||||||
Weight (kg)
|
24
|
|||||||||
Size (mm)
|
330W×580H×232D
|
|||||||||
Protection Degree
|
IP65
|
|||||||||
Installation Style
|
Wall-mounted
|
|||||||||
Warranty
|
5 years
|
Packing & Delivery
Applications
Contact Us